The smallest UL recognized motor protector sealed in PBT enclosure (Stronger than   UP6  )
More than 10 million units shipped per annum (2009)
More than 30 years of long-seller
Japan / Hong kong / Europe, three global production sites
Recognized by UL for Motor Protector
@
Operating
Temp

Tolerance
Differential
Temp
Breaking capacity
4A 125V AC 6000 cycle (resistive)
2.5A 250V AC 10000 cycle (resistive )
Model
Agency
Standard
Category
Electrical Ratings
Max Temp
File No.
UP71
UP72
UL
UL2111
Motor Protector
125V /250V AC 0.373kW
150C
E52703
c-UL
CSA C22.2 No.77
Motor Protector
125V /250V AC 0.373kW
150C
E52703
c-UL
CSA C22.2 No.77
Motor Protector
1.5A 125V AC (FLA)
150C
E52703
c-UL
CSA C22.2 No.77
Motor Protector
1.25A 250V AC (FLA)
150C
E52703
CQC
GB 14536.10
Thermostat
iNon-fused bimetal type)
4A 125V, 2.5A 250V AC
150C
CQC04002009091
CQC03002008321
UP7
UP71
UP72
EN(VDE)
EN60730-2-2
Thermal Motor Protector
250V AC
150C
892100-
4510-0026
EN(VDE)
EN60730-2-9

Thermal Cut-out

2.5A(1.6A)/250V AC
resistive(inductive)
10000 cycles
150C
892100-
4510-0027
EN(VDE)
EN60730-2-9
Thermal Cut-out
0.5A/250V AC
(resistive) 100000 cycles
150C
892100-
4510-0027
Mounting method
In case of sensing heat directly from the heat source, place the motor protector to touch itfs opposite surface of gUCHIYAh printed surface to the heat source.
*In case of sensing convection heat or heat emission, please contact Uchiya.
The condition of sensing heat differ case by case.
@
Overheating protection
Small motor
transformer
Power Supply
Lighting Fixture
Projector
uchiya logo